What are the specifications of the wire and cable

RVVP shielded wire: copper core PVC insulated shielded PVC sheathed flexible cable, voltage 300V/300V 2-24 core Uses: instrument, meter, intercom, monitoring, control installation

 

RG: Physically foamed polyethylene insulated access network cable, used to transmit data and analog signals in the coaxial optical fiber hybrid network (HFC)

 

KVVP: PVC sheathed braided shielded cable Uses: signal transmission, control and measurement of electrical appliances, meters, and power distribution devices

 

RVV sheathed wire (227IEC52/53) PVC insulated flexible cable Purpose: household appliances, small electric tools, instruments and power lighting

AVVR PVC sheathed flexible cable for installation

 

SBVV HYA data communication cable (indoor and outdoor) is used for the connection of telephone communication and radio equipment and the junction box wiring of telephone wiring network

 

RV, RVP PVC insulated cables

 

RVS, RVB are suitable for household appliances, small electric tools, instruments, meters and power lighting connection cables

 

BV, BVR Polyvinyl Chloride Insulated Cable Purpose: Suitable for fixed wiring of electrical appliances, instrumentation and power lighting

 

RIB speaker cable (fever cable)

 

KVV PVC insulated control cable Purpose: signal transmission, control and measurement of electrical appliances, meters, and power distribution devices

 

SFTP twisted pair transmission telephone, data and information network

 

UL2464 computer cable

 

VGA monitor cable

 

SYV coaxial cable Transmission of radio frequency signals in wireless communication, broadcasting, monitoring system engineering and related electronic equipment (including comprehensive coaxial cables)

SDFAVP, SDFAVVP, SYFPY coaxial cable, dedicated for elevator

 

JVPV, JVPVP, JVVP copper core PVC insulated and sheathed copper wire braided electronic computer control cable

 

What are the commonly used wire and cable specifications

 

227 IEC 01(BV) 450/750 V 1.5-95;

 

227 IEC 02(RV) 450/750 V 1.5-25;

 

227 IEC 42(RVB) 300/300 V 0.5-0.75;

 

227 IEC 53(RVV) 300/500 V 0.75-2.5 (2-5 cores);

 

RVS 300/300 V 0.5-0.75;

 

227 IEC 10(BVV) 300/500 V 1.5-35 (2-5 core)

 

BVV 300/500 V 0.75-10 (1 core);

 

BVVB 300/500V 0.75-10 (2-3 cores);

 

AVR 300/300 V 0.08-0.4 (1 core);

 

AVRS 300/300 V 0.12-0.4 (2 cores);

 

AVVR 300/300 V 0.12-0.4 (2-24 core);

 

RVVP 300/300 V 0.12-0.4 (4-24 core);

 

The wire square specification circuit design is generally:

 

The entrance line is 4-6mm², the lighting is 1.5mm², the socket is 2.5mm², and the air-conditioning line is 4mm².

 

After 2000, the circuit design is generally: entrance line 6-10mm², lighting 2.5mm², socket 4mm², air conditioning 6mm² dedicated line.

 

The wires used in home improvement are generally single-strand copper core wires, and their cross-sectional area mainly has three specifications, namely 4.0mm², 2.5mm² and 1.5mm². In addition, there are 6.0mm² specifications, which are mainly used for home main lines, 4.0mm² specification single-strand copper core wires are used for circuit main lines and special wires for air conditioners, electric water heaters, etc., and 2.5mm² specification single-strand copper core wires are used for socket wires and For some branch lines, 1.5mm² single-strand copper core wire is used for lamps and switch wires, and the ground wire in the circuit generally also uses 1.5mm² single-strand copper core wire.


Post time: Jan-26-2021